The filter is intended for respiratory protection (complete with the facepiece) against organic gases and vapors with a boiling point of above 65°Ñ, as well as inorganic and acid gases and vapors. It has an increased action period.
- The pair of filters are used together with a half-mask 7.877 (small size), 7.878 (medium size), 7.879 (large size) or with a full mask7.880.
- Provides protection at an oxygen content of not less than 17% and total vaporous and gaseous noxious agent content of at most 50 MPC (with insulating half mask) and at most 0.1 vol.% (with panoramic mask).
- To provide additional protection against aerosols, the following prefilters are fixed to the gas filters with prefilter holder 7.889: 7.886 (Ð1), 7.887 (Ð2), 7.888 (Ð3, to order)
- The operation range of temperature is from −40 to +40°Ñ.
Guaranteed shelf life: 5 years.
Weight: 130 g.
TR CU 019/2011
EN 14387
Products are sold in pairs.